{"id":243,"date":"2015-04-25T02:00:32","date_gmt":"2015-04-25T02:00:32","guid":{"rendered":"http:\/\/desanderdesilter.com\/?p=243"},"modified":"2015-04-25T03:00:26","modified_gmt":"2015-04-25T03:00:26","slug":"the-method-of-use-mud-cleaner","status":"publish","type":"post","link":"http:\/\/desanderdesilter.com\/index.php\/2015\/04\/25\/the-method-of-use-mud-cleaner\/","title":{"rendered":"The method of use mud cleaner"},"content":{"rendered":"<p>The correct installation and use of<a href=\"http:\/\/www.gnsolidsamerica.com\/mud-cleaner.html\"><strong> hydrocyclone mud cleaner<\/strong><\/a> can filter unwanted solids from the mud to achieve controlled velocity.\u00a0 It is important to use mud cleaner properly to ensure the quality of treated drilling mud.<\/p>\n<p><a href=\"http:\/\/desanderdesilter.com\/wp-content\/uploads\/2015\/04\/mud-cleaner-1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-244\" src=\"http:\/\/desanderdesilter.com\/wp-content\/uploads\/2015\/04\/mud-cleaner-1-288x300.jpg\" alt=\"mud cleaner 1\" width=\"288\" height=\"300\" \/><\/a><\/p>\n<ol>\n<li>The correct position of hydrocyclone mud cleaner for<a href=\"http:\/\/www.gnsolidsamerica.com\/drilling-mud-circulating-system.html\"><strong> whole mud system<\/strong><\/a> is behind shale shaker which filter large solids at first step.<\/li>\n<li>The drilling mud prior enter the hydrocyclone must be processed through <a href=\"http:\/\/www.gnsolidsamerica.com\/linear-motion-shale-shaker.html\"><strong>shale shaker first<\/strong><\/a>.<\/li>\n<li>Check the power source and once motor is start, check direction of rotation of the motor rotate in correct direction.<\/li>\n<li>Seeking unusual noise from motors after turn on the machine<\/li>\n<li>Secure the screen and hand feel the strength of the screen.\u00a0 Initiate the test-run fluid and check if screens are intact.\u00a0 Check every moving parts while machine is on<\/li>\n<li>Clean the screen by end of each shift to prevent blockage of mesh and extend <a href=\"http:\/\/www.gnsolidsamerica.com\/shale-shaker-screen.html\"><strong>the usage life of screen<\/strong><\/a><\/li>\n<li>Stop the feeding of mud should turn off the pump first and keep on the shale shaker for another few minute and wash the screen, then shut down the shale shaker<\/li>\n<li>Re-grease the bearing as needed for proper moving on machine parts<\/li>\n<li>When the feed liquid pressure equal to the rated pressure, turn off the valve on the overflow tube, make the tubular value of the overflow pipe is 0.01-0.03mpa. When the feed pressure below the rated pressure, adjust the valve on the over-flow, make the tubular value of the overflow pipe is .0.02-0.05mpa.<\/li>\n<li>For every 500 operation hours, the machines need regulator maintenances by checking moving parts and replace parts as necessary.<\/li>\n<li>For every 4000 operation hours, the machine needs overhaul by doing maintenance list above and replace the hydrocyclone and check that insulation of electrical parts of the machine.<\/li>\n<\/ol>\n<p>&nbsp;<\/p>\n<p>Related Arciels:<\/p>\n<ul>\n<li><a href=\"http:\/\/drillingmudcleaner.com\/why-now-have-big-discount-is-it-in-good-condition\/\">Why now have big discount, is it in good condition?<\/a><\/li>\n<li><a href=\"http:\/\/www.myprgenie.com\/view-publication\/1000hp-drilling-rig-mud-system-for-russia\">1000HP Drilling Rig Mud System for Russia<\/a><\/li>\n<li><a href=\"http:\/\/www.mudcentrifuge.com\/post\/117301166471\/gn-vertical-cuttings-dryers-and-decanter\">GN Vertical Cuttings Dryers and Decanter Centrifuges Working for SINOPEC Soon<\/a><\/li>\n<li><a href=\"http:\/\/www.prlog.org\/12449663-the-operation-of-decanter-centrifuge.html\">The operation of decanter centrifuge<\/a><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>The correct installation and use of hydrocyclone mud cleaner can filter unwanted solids from the mud to achieve controlled velocity.\u00a0 It is important to use mud cleaner properly to ensure the quality of treated drilling mud. The correct position of hydrocyclone mud cleaner for whole mud system is behind shale shaker which filter large solids &hellip; <a href=\"http:\/\/desanderdesilter.com\/index.php\/2015\/04\/25\/the-method-of-use-mud-cleaner\/\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;The method of use mud cleaner&#8221;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[],"tags":[],"class_list":["post-243","post","type-post","status-publish","format-standard","hentry"],"_links":{"self":[{"href":"http:\/\/desanderdesilter.com\/index.php\/wp-json\/wp\/v2\/posts\/243","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/desanderdesilter.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/desanderdesilter.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/desanderdesilter.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/desanderdesilter.com\/index.php\/wp-json\/wp\/v2\/comments?post=243"}],"version-history":[{"count":0,"href":"http:\/\/desanderdesilter.com\/index.php\/wp-json\/wp\/v2\/posts\/243\/revisions"}],"wp:attachment":[{"href":"http:\/\/desanderdesilter.com\/index.php\/wp-json\/wp\/v2\/media?parent=243"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/desanderdesilter.com\/index.php\/wp-json\/wp\/v2\/categories?post=243"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/desanderdesilter.com\/index.php\/wp-json\/wp\/v2\/tags?post=243"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}